NIST WTC FINDINGS
John Glenn, MBCI
Enterprise Risk Management/Business Continuity
OK, I'm a slow reader; I just got around to reading the NIST news release of
October 1, 2008 titled "Safer Buildings Are Goal of New Code Changes Based on
Recommendations from NIST World Trade Center Investigation." Just reading the
title takes awhile.
The blurb, at http://www.nist.gov/public_affairs/releases/wtc_100108.html,
lists NIST "23 major and far-reaching building and fire code changes approved
recently by the International Code Council (ICC) for incorporation into the
2009 edition of the ICC's I-Codes (specifically the International Building
Code, or IBC, and the International Fire Code, or IFC), that are used as the
basis for building and fire regulations promulgated and enforced by U.S.
state and local jurisdictions. Those jurisdictions have the option of
incorporating some or all of the code's provisions but generally adopt most
provisions."
Several of the changes, and a number of the "rejected for 2009"
recommendations caught my attention.
FROM THE DOCUMENT
The following are the 23 model building and fire code changes consistent with
the NIST WTC investigation recommendations now required by the I-Codes
(changes displayed in italics are ones that were approved at previous ICC
hearings and incorporated at the Minneapolis hearing into the 2009 I-Codes):
* An additional (third) exit stairway for buildings more than 420
feet high.
* An increase of 50 percent in the width of exit stairways in new
sprinklered buildings.
* Permitting the use of elevators for occupant evacuation in fires
and other emergencies for all buildings, and as an alternative to the
required additional exit stairway for buildings more than 420 feet high.
Passenger elevators must meet specific criteria to be used for evacuation
purposes.
* Hardening of exit stairway and passageway enclosures, and elevator
shaft enclosures, in buildings—for all buildings more than 420 feet high, for
buildings 75-420 feet high where failure of the enclosure would substantially
jeopardize human life, and in essential facilities such as hospitals.
* Separating exit stairway enclosures by a distance not less than 30
feet or not less than one-fourth of the maximum building diagonal, whichever
is less. For example, a building with a 50-foot by 50-foot floor plan would
have a diagonal of about 70 feet. One-fourth of 70 is 17.5 feet, which would
be the minimum distance required between exits (since it is less than 30
feet).
* A minimum of one fire service access elevator for buildings more
than 120 feet high.
* Fire service access elevator lobby sizes that are a minimum of 150
square feet in area with sides at least 8 feet long.
* Keeping fire service access elevator lobbies free of storage.
* Greater reliability of sprinklers with a minimum of two water
supply risers for each sprinkler zone in buildings more than 420 feet high.
Each riser is required to supply sprinklers on alternate floors and will be
placed in remotely located stair enclosures.
* Providing minimum structural integrity for framed and bearing wall
structures
* A one-hour increase in the fire-resistance rating of structural
components and assemblies in buildings more than 420 feet high.
* Explicit adoption of the "structural frame" approach to fire
resistance ratings that requires all members of the primary structural frame
to have the higher fire resistance rating commonly required for columns. The
primary structural frame includes the columns; other structural members
including the girders, beams, trusses and spandrels having direct connections
to the columns; and bracing members designed to carry gravity loads.
* Broadening the definition of the primary structural frame to
include bracing members essential to vertical stability (such as floor
systems or cross bracing) whether or not they carry gravity loads.
* Increasing bond strength for fireproofing to nearly three times
greater than currently required for buildings 75-420 feet high and seven
times greater for buildings more than 420 feet high.
* Field installation requirements for fireproofing to ensure that:
* installation complies with the manufacturer's
instructions;
* the substrates (surfaces being fireproofed) are clean and
free of any condition that prevents adhesion;
* testing is conducted to demonstrate that required adhesion
is maintained for primed, painted or encapsulated steel surfaces; and
* the finished condition of the installed fireproofing, upon
complete drying or curing, does not exhibit cracks, voids, spalls,
delamination or any exposure of the substrate.
* Special field inspections of fireproofing to ensure that its as-
installed thickness, density and bond strength meet specified requirements
and that a bonding agent is applied when the bond strength is less than
required due to the effect of a primed, painted or encapsulated steel
surface. The inspections are to be performed after the rough installation of
mechanical, electrical, plumbing, sprinkler and ceiling systems.
* Luminous markings delineating the exit path (including vertical
exit enclosures and passageways) in buildings more than 75 feet high to
facilitate rapid egress and full building evacuation.
* Broadening the use of luminous markings to identify obstacles,
exit doors, exit signs and floor numbers in the exit path in buildings more
than 75 feet high.
* Luminous exit path markings in existing buildings more than 75
feet high with the exception of open, unenclosed stairs in historic
buildings.
* Increasing the area of the Fire Command Center (the area from
which all fire department operations are directed and usually housing the
control panel for alarms, sprinklers, etc.) from 96 square feet to 200 square
feet with at least one side 10 feet long in buildings more than 75 feet high.
* Approved radio coverage for all buildings for emergency responders
within the building based upon the existing coverage level of public safety
communications systems at the exterior of the building. Approved coverage
includes specific requirements for signal strength, system design,
installation and maintenance.
* Installing an emergency responder radio communications system to
provide the required level of radio coverage throughout a building. Typical
hardwired communications systems would be replaced.not approved for the 2009 edition of the I-Codes but will be
considered for resubmission at a later date after being amended:
* Requiring buildings more than 420 feet high to be designed to
survive a building contents fire to burnout without more than local failure
of the structural frame.
* Requiring structures not to suffer a collapse disproportionate to
a local initiating failure caused by an accident or incident.
* Requiring a risk assessment and acceptable mitigation of risks for
buildings more than 420 feet high with an occupant load greater than 5,000;
for buildings with an occupant load greater than 10,000; and for buildings
determined to be at higher than normal risk.
* Requiring use of a new standard for conducting wind tunnel
testing.
* Requiring installation of stairway communication and monitoring
system at every fifth floor of each exit stairway. Also requiring, in
buildings more than 75 feet high, a video surveillance system in each exit
stairway, elevator lobby, elevator hoistway and elevator machine room to
enhance situational awareness of emergency responders.
* Requiring fire safety and evacuation plans for all
occupancies and buildings where required by the International Fire Code (the
International Building Code is more widely adopted across the country than
the IFC; this would ensure all situations are covered).
* Requiring detailed schematic building plans,
including an approved Building Information Card, to be located in fire
command centers to show the type of construction, stairway access and
pressurization, fuel oil tank and hazardous materials locations, standpipe
availability and locations, in addition to typical floor plan and details of
the building core, means of egress, elevator locations, fire protection
systems, firefighting equipment and fire department access.
* Limiting the length of horizontal transfer corridors used to
connect a stairwell to 50 feet or less in buildings more than 75 feet high.
Allowing the option to design buildings more than 420 feet high using the ICC
Performance Code, instead of the high-rise provisions of the International
Building Code. This change will allow the performance-based NIST WTC
recommendations to be considered in a holistic manner.
SIMPLE, LOW-COST OPTIONS REJECTED
As an Enterprise Risk Management practitioner I consider some of the
recommendations to be in the "Duh!" category - "Isn't it OBVIOUS?"
As an Enterprise Risk Management practitioner, I have to wonder how some very
simple, very low cost recommendations were rejected for inclusion in the 2009
code update.
You already may have guessed, by the red characters
above which omissions I find particularly upsetting.
I am not a structural engineer and, frankly, I would never volunteer to work
more than three or four stories above ground level, so I am not qualified to
comment on the structural considerations.
We have discussed use of elevators as evacuation vehicles in the past and,
with air pressure controlled to prevent fire and fumes from entering the
elevator shaft - as they are prevented from entering the emergency stairwells
- their time has arrived.
But to exclude
* Requiring a risk assessment and acceptable mitigation of risks for
buildings more than 420 feet high with an occupant load greater than 5,000;
for buildings with an occupant load greater than 10,000; and for buildings
determined to be at higher than normal risk.
* Requiring fire safety and evacuation plans for all occupancies and
buildings where required by the International Fire Code (the International
Building Code is more widely adopted across the country than the IFC; this
would ensure all situations are covered)
and
* Requiring detailed schematic building plans, including an approved
Building Information Card, to be located in fire command centers to show the
type of construction, stairway access and pressurization, fuel oil tank and
hazardous materials locations, standpipe availability and locations, in
addition to typical floor plan and details of the building core, means of
egress, elevator locations, fire protection systems, firefighting equipment
and fire department access.
seems, well, foolish.
Why would anyone put off creation of "a risk assessment and acceptable
mitigation of risks" for buildings of ANY size unless of course the people
pushing back (a) don't work/visit the structure or (b) consider human life a
"replaceable commodity." As an Enterprise Risk Management practitioner I
never would limit the risk assessment to only those structures of a certain
size or capacity.
I particularly am bothered two words in the fire safety and evacuation plans
statement: "where required" - I don't care what organization does or does not
require these plans; the plans are needed to protect personnel in the
building, both tenants and visitors. I rant and rave, froth at the mouth and
roll around on the floor because fire safety and evacuation plans aren't
posted all over the floor - near every exit and every congregation point
(e.g., break room, water cooler).
All things considered, how much can it cost vs. loss of life or cost of the
structure, to post fire safety and evacuation plans - essentially evacuation
maps - around the structure?
As far as requiring detailed schematic building plans, including an approved
Building Information Card, to be located in fire command centers to show the
type of construction, stairway access and pressurization, fuel oil tank and
hazardous materials locations, standpipe availability and locations, in
addition to typical floor plan and details of the building core, means of
egress, elevator locations, fire protection systems, firefighting equipment
and fire department access, this information should be available from the
architects in the first place; I fail to see why anyone would push back on
this recommendation.
I confess there are a "few" more items I would like NIST to include in its
list, things such as tornado and earthquake-proof construction - tornado-
proof in all locations, earthquake proof in most locations (check your local
fault map; chances are, your building is close to a fault).
I once worked as a business continuity consultant for a pretty progressive
company.
But as progressive as it was, it failed to include a business continuity
person when it went looking for a new building and later when it positioned
the critical functions in that building.
Turns out the building was in a flood plain and the critical business
function was on the building's first floor.
That was the first time I realized if might be a good idea to include someone
"risk conscious" in more than simply "business continuity" planning.
But, neither my progressive client nor NIST asked me for my two cents.